Low-Cost Remote Power Reboot Switch with NEMA 5-15R Outlet
PWR-RMT-RBT-515R-LC
The ENVIROMUX Remote Power Reboot Switch allows you to remotely reboot and control power (on/off) to a server or other powered device over IP.
- Regulatory approvals: FCC.
- Auto-scheduler allows for scheduling power on/off/reboot events.
- Easy-to-use web interface and Android/iPhone app makes it easy to control power from anywhere in the world.
- Control an unlimited number of Remote Power Reboot Switches from one Android/iPhone device(restricted by storage space).
- Up to four devices can control one Reboot Switch.
- Checks network connection and can automatically reboot device if there is no response.
- This feature is not supported for private networks.
- The Remote Reboot Switch is the ideal solution for many applications, such as:
- Remote reboot of any device, router, server, kiosk, etc. The device need not be network attached.
- Secure sensitive devices by keeping them powered off when not in use. This prevents hackers from detecting them at all times.
- Power down equipment when not needed for power savings and to save on wear and tear.
- Power up alert devices like sirens, lamps, and messages, or environmental system like heaters, coolers, pumps, etc.
Power
- 125 to 250 VAC at 50 or 60 Hz. 10A fuse.
- Input connector: one IEC 320 C14 plug.
- Output connector: one NEMA 5-15R receptacle.
- Includes 10A line cord and extension cord.
Network Interface
- One 10/100 Base-T Ethernet port with RJ45 Ethernet connector.
- 6 ft (2 m) flat CAT5 cable included
Protocols
- HTTP, TCP/IP, UDP, Dynamic DNS, DNS Client, DHCP.
Environmental
- Operating temperature: 32 to 140°F (0 to 60°C).
- Operating and storage relative humidity: 10 to 90% non-condensing RH.
Dimensions
- WxDxH: 3.63x3.38x2.38 in (92x86x60 mm).
Regulatory Approvals
- FCC
Warranty
- Two years
Question: Please let me know if I can use a management tool to take control of several boxes as a centralized solution. Thanks.
Answer: Thank you for your inquiry. The NTI PWR-RMT-RBT-515R-LC solution can be controlled via a web interface as well as iPhone/Android. Any number of devices can be added and controlled as well, storage permitting.
Question: Can this device be set to periodically reset power automatically? Let's say every week and perform a power cycle for 10 seconds?
Answer: Thank you for your inquiry,
This NTI PWR-RMT-RBT-515R-LC has the ability to configure 6 Monday-Sunday dates and times to either turn on, turn off, or reset the outlet. Unfortunately the reset time is not configurable on this unit and when the unit does reset, the outlet remain off for 4 seconds.
The PWR-RMT-RBT-LC unit has 8 configurable times, each one can be configured to repeat the action every x days, to turn the outlet on/off or cycle the outlet. The cycle time can be adjusted from the default of 10 seconds if so desired.
Question: Can the power/reboot be controlled via an API or script?
Answer: Thank you for your inquiry,
The NTI PWR-RMT-RBT-515R-LC does not have API or support scripting but you can control the unit via an Android or apple phone Download and install the free application "EZOUTLET" via the iOS App Store or Google Play Store.
That being said, this similar NTI PWR-RMT-RBT2-515R-LC remote reboot unit does support command line interface.
For more remote reboot products with API and CLI support, I would also recommend taking a look at the Dataprobe iBoot series.
Answer: Thank you for your inquiry. The NTI PWR-RMT-RBT-515R-LC solution can be controlled via a web interface as well as iPhone/Android. Any number of devices can be added and controlled as well, storage permitting.
Question: Can this device be set to periodically reset power automatically? Let's say every week and perform a power cycle for 10 seconds?
Answer: Thank you for your inquiry,
This NTI PWR-RMT-RBT-515R-LC has the ability to configure 6 Monday-Sunday dates and times to either turn on, turn off, or reset the outlet. Unfortunately the reset time is not configurable on this unit and when the unit does reset, the outlet remain off for 4 seconds.
The PWR-RMT-RBT-LC unit has 8 configurable times, each one can be configured to repeat the action every x days, to turn the outlet on/off or cycle the outlet. The cycle time can be adjusted from the default of 10 seconds if so desired.
Question: Can the power/reboot be controlled via an API or script?
Answer: Thank you for your inquiry,
The NTI PWR-RMT-RBT-515R-LC does not have API or support scripting but you can control the unit via an Android or apple phone Download and install the free application "EZOUTLET" via the iOS App Store or Google Play Store.
That being said, this similar NTI PWR-RMT-RBT2-515R-LC remote reboot unit does support command line interface.
For more remote reboot products with API and CLI support, I would also recommend taking a look at the Dataprobe iBoot series.